Home|About Us|Contact Us|Sales & Service|Stocking Distributors|Manuals|Catalog|Telecom Division|EV Division|Product Registration

Battery Chargers
DC-AC Inverter-Chargers
DC-DC Converters
Power Supplies
Power Modules & Power Function Manager
DC Power Conditioners
Battery Isolators & Integrators
DC Power Accessories
Electrical Panels
Digital Instruments For AC/DC Systems
Metering
Electrical Panel Accessories
AC Source Switches & Panels
Galvanic Isolators And AC Shore Power Accessories
Terminal Strips, Connector Strips & Bus Bars
Thru-Dex Waterproof Junction Boxes
Electrical Enclosures, Cable Entries
Thru-Dex Cable Glands & Antenna Accessories
Grounding & Noise Filters
Test Equipment
Phone-Coms, Radio Covers, & Hailers
Phase Three Modular Battery Chargers

A New Battery Charging System with Redundant, Easily Replaced Charge Modules Providing High Reliability and Serviceability

Reliability
• Redundant, independent, charger modules increase reliability–a   malfunction of one does not disable the charging system;
  remaining modules continue to operate.

Serviceability
• Module change-out takes only minutes, while the system
  continues to operate
• Technical personnel not required
• No need to remove the charger case from the boat or
  disconnect any wiring
• No inconvenience of power interruption to the boat

Features
• Three stage “smart” charging; bulk, absorption, float
• Battery type selector switch; gel-cell, lead-acid, AGM
• Temperature compensated output option
• Numerous diagnostic and system status indicators
• 12 Volt; 33-100 amps or 24 Volt; 22-67 amps
• “Universal” input of 90-264 VAC, 50-60 Hz.–can be used
  anywhere in the world
• Powder coated stainless steel case


The Phase Three Modular (PTM) Concept
Super yachts and commercial vessels have complex electrical systems that support equipment essential to safe operation. These boats are frequently in transit or in remote locations where repair/service is not readily available. Down-time can be very costly and severely impact sailing schedules.

Recognizing that all equipment has a finite service life and random component failure can occur at any time, system reliability can be improved by reducing the number of single points of failure, thus diminishing the impact of a solitary fault on the overall system. The PTM series applies this “fault-tolerant” concept to battery chargers, by using multiple independent charger modules within the unit.

The PTM consists of a case which serves as connection point to AC input and battery bank output, as well as three front-facing power bays, each accommodating a 550 watt charger module which slides and locks in place. If a module fault occurs, a front panel indicator is activated and the system continues operating.

Captains and owners will appreciate this system approach to reliability. A dead charger and dead batteries can disable a vessel, but with the PTM redundant charging system a fault in one of the modules is easily identified and it can be quickly replaced with an on-hand spare or an exchange unit from the factory, while the charging system
continues to operate.

The Phase Three Modular (PTM) Series is a battery charging system consisting of a wall mount case, which serves as a connection point for AC input and battery bank output that accommodate up to three charging modules which slide and lock into front access power bays. Its redundant charger modules increase reliability, as the system remains operational in the event of a charger module fault. The system is easily and quickly restored to full output by simple module replacement.

The system features three stage charging for rapid recharge and optimal battery life. Click here for a complete description of the three stage charging process.

Specifications
System
Model
Modules
Installed*
Max Output
Amps
Max Input Amps
@ 115/230 VAC
PTMS-12-100
3
100 @ 12 V
18/9
PTMS-24-67
3
67 @ 24 V
18/9

General System Specifications
Input Voltage/Frequency: 90-264 VAC, 47-63 Hz, single phase; derate linearly
from 100% output @ 105 VAC to 80% output @ 90 VAC
Power Factor: .96-.99
Efficiency: 85% typical
Nominal Charge/Float Voltages: Refer to chart on page 5
Temperature Compensation (Option): - 5 mV per cell per °C (typical)
Temperature Rating: 0-60° C; derate linearly from 100% output @ 50° C to 80% output @ 60° C
Recommended Battery Type/Capacity: Gel-Cell, Flooded or Sealed Lead-Acid;
12 Volt Systems: 6 Cell, 80-400 A-H (per installed module); 240-1200 A-H (per system)
24 Volt Systems: 12 Cell, 40-200 A-H (per installed module); 120-600 A-H (per system)
Output Battery Banks: 3
Module Bays: 3*
Status Indicators: Output OK, No Output, Check System, Battery Too Hot, Total
Output Bar Graph, Output Voltage Test Points, Contacts for Optional Remote Alarm
Case Material: Powder Coated Stainless Steel
Case Size: Refer to diagram at right
Weight: Empty: 16 lbs/7.3 kg. - With three modules installed: 34 lbs/15.5 kg.
* Note: Charge modules are shipped in the same carton as the PTM case and are then
placed in position by the installer.

Individual Module Specifications
Models: PTM -12-33 (12 volt); PTM-24-22 (24 volt)
Input Voltage/Frequency: 90-264 VAC; 47-63 Hz; derate linearly from 100%
output @ 105 VAC to 80% output @ 90 VAC
Input Current: 3 amps @ 230VAC; 6 amps @ 115 VAC
Power Factor: .96-.99
Efficiency: 85% typical
Protection Features: Input Fuse, Output Fuse, Current Limiting, Over Voltage
Protection, Cooling Fan, Automatic Thermal Shutdown/Recovery
Compliances:
CE Mark, UL Recognized; E183223, Level 3
Safety: EN60950-1 USA, Canada, Europe
EMI Radiated and Conducted: FCC Part 15 Level A; EN55022 Class A
Status Indicators: Output OK/FAULT
Weight: 6 lbs.
Output Current:
PTM-12-33: 33 amps max
PTM-24-22: 22.5 amps max in Bulk Phase; 20 amps max in Absorption/Float Phases

Options
Temperature Compensation Sensor - Model TCS-12/24: Click here for details
Case Size
Inches
Centimeters
H
W
D
H
W
D
20.9
10.9
8.8
53.1
27.7
22.4