| ES-1 DC Master Panel This DC master control panel offers a large DC circuit capacity and full metering. |
![]() |
Because of their exact height match and style compatibility, the panels below are ideal companions
for expanding circuit capacity of the ES-1 or ES-5, or they may be used as stand-alone load centers.
![]() |
ES-6 DC Load Center Features: • Accommodates one meter; analog standard. (DC 0-50A ammeter standard), or specify DC volts • Master breaker (DC-75 amp standard; 50 or 100 amp optional, single pole) • 10 branch circuit capacity, 8 installed standard: 1-5A, 2-10A, 4-15A, 1- 20A • Indicator lights on every circuit. • LS-III set included. • Multiple position ground bus bar included. • size: 5 1/4"W x 15"H x 4" D, (13.3 x 38.1 x 10.2 cm) Download PDF Order form |
| ES-7 AC or DC Accessory Panel Features: • AC or DC master breaker (AC 50 amp* standard, 30 amp optional, double pole or DC 100 amp standard; 50 or 75 amp optional, single pole.) • 16 branch circuit capacity, 12 installed standard: ES-7A: 2-10A, 5-15A, 5-20A ES-7D: 2-5A, 3-10A, 5-15A, 2-20A • Indicator lights on every circuit. • LS-III label set included. • Multiple position ground bus bar included. • Size: 5 1/4"W x 15"H x 4"D, (13.3 X 38.1 X 10.2 cm) Weight: 7 lbs., (3.2 Kg.) * Note 50 amp master OK for use on 230 VAC line-to-line systems. For 230 VAC line-to-neutral systems 30 amp is maximum master breaker value. Download PDF Order form |
![]() |
AC-DC Master Control Panels
Locating all AC and DC functions on one panel provides a vessel with a central load distribution and monitoring center. Features common to all models include:
• Complete metering of voltage and current on AC and DC systems. Back-lit analog meters are standard.
• AC master breaker(s) with reverse polarity warning light.
• Power "on" indicator lights on all circuits.
• four battery bank voltage test switch
• Deluxe label set (LS-III) included, 206 functions.
• Multiple position ground bus bar
• Rating 115/230 VAC, 65 VDC
| ES-3 This panel combines AC and DC control into one compact panel. See list of specifications at bottom of page. 13.7W” X 10”H X 4” D 10 lbs (34.8 X 25.4 X 10.2 cm 4.5Kg.) Download PDF Order form |
![]() |
| ES-4 Large 3 1/2" scale meters and an ample circuit breaker capacity makes this the panel of choice for boats in the 35'-45' range. Circuit specifications listed at bottom of page. 17”W X 12”H X 4” D 12 lbs (43.2 X 30.5 X 10.2 cm 5.5Kg.) Download PDF Order form Option . |
![]() |
| ES-5 Exceptional yachts require an extraordinary panel which incorporates all the aspects of the vessel's electrical system. The ES-5 is such a panel. In addition to its large DC circuit capacity, the AC section includes two load groups and a source selector switch for two shore power lines and a 15kW generator. Pre-heat and start-stop controls are standard. additional system capacity can be obtained by incorporating model ES-6 or ES-7 (listed on page 16). 20" W x 15" H x 6" D 20 Lbs. (50.8 X 38.1 X 15.2 cm, 9.1Kg.) Download PDF Order form |
![]() |
|
Model
|
DC Circuits | AC Circuits |
|
ES-3
|
16 Breaker capacity, 12 Installed standard;2-5A, 3-10A, 4-15A, 3-20A or specify
|
Master (D.P.) 30 amp standard 50 amp* optional, plus 6 S.P. branch capacity, 5 installed standard; 1-10A, 15A, 2-20A or specify
|
|
ES-4
|
20 Breaker capacity, 16 Installed standard; 3-5A, 3-10A, 5-15A, 5-20A or specify
|
Master (D.P.) 50 amp* standard plus 8S.P. branch capacity, 6 installed standard; 1-10A, 3-15A, 2-20A or specify
|
|
ES-4SS
|
Same as above with 7.5 kW, three position (Shore-Off-Gen) ship shore selector switch installed. Special Order Only.
|
|
|
ES-5
|
Master plus 24 breaker capacity, 20 installed standard; 3-5A, 4-10A, 7-15A, 6-20A or specify
|
Two load groups each consisting of: Master breaker (D.P.) 50 amp* standard plus 10 S.P. branch capacity, 8 installed standard; 2-10A, 3-15A, 3-20A or specify
|
Options
Meters:
Standard installed voltmeters are for 12 VDC or 115 VAC applications. (Ammeter range depends on master breaker value.) Optional voltmeters may be installed for 24 VDC or 230 VAC applications. Contact the factory for a complete list of metering options
Alternate Circuit Breaker Configurations:
Changing circuit breaker value mix or location is never a problem! Simply advise us of the breaker arrangement you need. (An illustrated order form listing all options is available upon request.) Please allow 3-5 days additional lead time to complete the modification.
Note: There is a mod. fee for special configurations contact factory.
Installation Cut-Out Dimensions
|
Model
|
Inches
(H x W) |
Centimeters
(H x W) |
|
ES-1
|
9 X 14
|
22.9 X 35.6
|
|
ES-3
|
13 X 8.8
|
33 X 22.4
|
|
ES-4
|
16.8 X 10.8
|
42.7 X 27.4
|
|
ES-5
|
19 X 13
|
48.3 X 33
|
|
ES-6D
|
4.5 X13
|
11.4 X 33
|
|
ES-7A & 7D
|
4 X 13.8
|
10.2X 35.1
|